Rack Mounted Load Bank for Testing PDU in Data Center Application
Basic Info.
| Color | Customized |
| Power | 7kw |
| Weight | 17kg |
| Transport Package | Plywood |
| Specification | 6U |
| Trademark | Triumph Load |
| Origin | China |
| HS Code | 9030339000 |
| Production Capacity | 5000 Set/Year |
Product Description
Product Description
Rack Mounted Server load banks provide accurate loading solutions for critical UPS & data center power applications and heat load testing. The rack-mounted servers are designed to be accurate, reliable, and easy to use for data center or test personnel.
This unit has small volume and can simulate the on-site server load. Heating element designed by special alloy resistance. In the medium and small power heating occasions, the alloy resistance element has the advantages of small temperature drift, long service life and high precision.
Hebei Kaixiang Electrical Technology Co., Ltd is a leading manufacturer in emergency power supply test & maintenance industry. Specialized in the design, R&D, manufacture of the high capacity AC & DC load bank, it owns the professional intelligent power supply testing equipment R & D centre in China. Kaixiang offer one-stop solutions to generator set & battery & UPS power manufacturers. Its products are widely used in data centre, shipbuilding, offshore platform, state grid, nuclear power, hospital, communication, railway etc filed. Kaixiang is strategy partner of many famous company, such as Cummins, Kohler, Jiangnan Shipyard, CSSC,CSIC, State grid, China mobile, Tecent, Baidu, CETC etc. Some of its products have been exported to America, Singapore, Israel, Japan, United Kingdom, Saudi Arabia, Australia, South Korea, Thailand, Sri Lanka, Angola etc. Through years of development, "Triumph Load" already famous brand in power supply detection industry in China.


| Rack Mounted Load Bank | |
| Rated Voltage/Hz | 1Phase AC230V/50Hz |
| Rated Power | Resistive:7kW; |
| Steps | Steps:A:0.5kW(A1),1kW(A2),2kW(A3);B:0.5kW(B3),1kW(B2),2kW(B1). Note:When the access voltage is lower than the rated voltage, the steps power change according to Ohm's law. |
| Power Factor | 1 |
| Precision | ≤5% |
| Fans Power | 1phase 230V/50Hz |
| Wiring | Load Input:C20 Wiring Location:Back of the enclosure |
| Insulation | F class |
| Protection | IP20 |
| Working Mode | Continuous |
| Cooling | Air cooled, front air intake, back air outlet |
| Dimension | 6U(431mm*266.7mm*500L*W*H) |
| Weight | Around 17kg |
| Working Environment | |
| Temperature | -10ºC +40ºC |
| Humidity | ≤95% |
| Altitude | ≤2500m |
| Air Pressure | 86~106kPa |