Basic Info.
Model NO. N6218-150-150
Operation Modes Cc,CV,Cp,Cr
Dynamic Mode up to 20kHz
Current Accuracy 0.1%+0.1%F.S.
Current Range 0-150A
Voltage Accuracy 0.05%+0.1%F.S.
Voltage Range 0-600V
Power Range 0-1800W
Communication Interface LAN/RS232
External Control Analog Programming Interface
Application Testing Power Supply and Battery
Transport Package Carton
Specification 2U, 19 inch
Trademark NGI DC Electronic Load
Origin China
HS Code 9030849000
Production Capacity 50000/Year
Product Description

N6200 Series Wide Range Medium Power DC Electronic Load
150V 150A 1800W Digital Controlled Electronic Load with Sequence Function for Automated Prototype Testing

      • Features
          • · High power density, minimizing space occupation
            · Stable and reliable CR/CP function supported by hardware
            · Editable rise and fall slew rate
            · Supporting Ethernet, serial communication and SCPI commands
            · Powerful charging & discharging control function mode, convenient for battery and supercapacitor test
            · Built-in ESR test function, supporting multiple industry standards and saving much cost for battery and supercapacitor users (Optional)
            · Dynamic mode up to 20kHz
            · Remote/local sense
            · Power-off memory function
            · Programmable sequence test function(SEQ), up to 100 groups sequence files, up to 50 steps per file
            · Editable Von/Voff, reducing test accidents
            · LCD screen for data display
            · Built-in auto test function, one-button operation for complex test tasks
            · Analog programming interface(APG), current monitoring interface, remote/local trigger function to realize complex function control and monitoring
            · Short-circuit simulation
            · Standard 19-inch 2U, available for rack installation

          • Product Introduction
            N6200 series is developed based on NGI's years of experience in testing for power supply and battery. It is with high accuracy, high reliability and high cost performance.N6200 series is with high power density and elegant appearance, which is available for benchtop use or installation in 19 inch rack.

            Application Fields

            • 1. Medium power supplies, battery packs, electrical tools, BMS, super capacitors, etc.



Our company is Shenzhen Scieo Electronic Co., Ltd. (Headquartered in Shenzhen, China)

We are a supplier of overall solutions for electronic test instruments from China. Our goal is to become lifelong partners with our clients, with an honest, pragmatic, responsible, and efficient work attitude.

What we offer:
1) Electrical signal test instruments: oscilloscopes, function generators, logic analyzers, source meters, multimeters, etc.;
2) Power test instruments: DC power supply, AC power supply, electronic load, feedback source-borne all-in-one machine, power meter, power analyzer, battery simulator, power amplifier, power signal source, etc.;
3) RF test instruments: LCR bridges, impedance analyzers, frequency counters, RF signal sources, signal (spectrum) analyzers, vector network analyzers, etc.;
4) EMC test instruments: electrostatic discharge generator, lightning surge generator, pulse cluster generator;
5) Safety test instruments: leakage current tester, withstand voltage tester, insulation resistance tester, ground resistance tester, etc.;
6) Temperature/humidity environment testing instruments: data collectors, multi-channel temperature recorders, thermal imagers, etc.;
7) Instrument accessories: probes, high-speed signal test fixtures, test cables, etc.


Why Choose Us:

1) OEM & ODM service: We turn your customized design into reality;2) Professional sourcing service: according to your needs, we look for the best producers, negotiate the best deals, and ensure the smooth delivery of products;3) Better price: professional purchasing team to ensure you get the best products and prices;4) Better Quality: We only purchase from trusted factories to guarantee reliability and performance;5) Personalized service: We will patiently understand your needs and customize solutions for you.

Please send your purchase requirements and technical specifications to our email, and we will reply to you as soon as possible.
FAQ
1. Are these products brand new?We guarantee that all the products we sell are new. All the products we sell are shipped directly from the manufacturer's warehouse to Shenzhen port to ensure that the goods received by customers are brand new.

2. How do I make the order?please provide your technical requirements, If you can, and then, our technical engineers will select the product model for you according to your requirements and make a proposal. After you have finalized the proposal and quotation, we will carefully process the order, from production to shipping, to ensure that the order goes smoothly.

3. How to ensure the quality of the products?All of our products have undergone strict quality inspection by the manufacturer to ensure that each product has passed the test and inspection.If it is a large quantity order, we will provide a sample trial first, and after the customer confirms that the product function meets the requirements, we will place an order for production to the manufacturer, and finally the manufacturer will directly ship the goods to the customer.

4. How to provide technical guidance?If you have any questions during use, please contact us, we have technical engineers, who can provide online technical guidance by video or email;

5.How to customize the products?Please provide the product specifications you need, we will choose the most powerful factory for you to customize samples according to your requirements, after you confirm the sample to meet your requirements, we will confirm the production with the manufacturer.If you have any other ideas, we encourage you to share them with us.
____________________________________________________________________________WE ARE VERY GOOD AT OFFERING CUSTOM MADE PRODUCTS FOR OUR CLIENTS.IF OUR PRODUCT INTERESTS YOU, PLS CONTACT US VIA EMAIL OR JUST A CALL!!!

Product Description

Model ChannelNumber Voltage Current Power Accuracy Resolution CommunicationInterface Size
N6206-60-10 1 60V 10A 600W Voltage≤0.05%+0.05%F.S./Current≤0.1%+0.1%F.S. 1mV/0.2mA LAN/RS232 2U
N6206-60-50 1 60V 50A 600W Voltage≤0.05%+0.05%F.S./Current≤0.1%+0.1%F.S. 1mV/0.9mA LAN/RS232 2U
N6206-150-50 1 150V 50A 600W Voltage≤0.05%+0.05%F.S./Current≤0.1%+0.1%F.S. 2.5mV/0.9mA LAN/RS232 2U
N6206-600-10 1 600V 10A 600W Voltage≤0.05%+0.05%F.S./Current≤0.1%+0.1%F.S. 10mV/0.2mA LAN/RS232 2U
N6212-60-100 1 60V 100A 1,200W Voltage≤0.05%+0.05%F.S./Current≤0.1%+0.1%F.S. 1mV/1.7mA LAN/RS232 2U
N6212-150-100 1 150V 100A 1,200W Voltage≤0.05%+0.05%F.S./Current≤0.1%+0.1%F.S. 2.5mV/1.7mA LAN/RS232 2U
N6212-600-20 1 600V 20A 1,200W Voltage≤0.05%+0.05%F.S./Current≤0.1%+0.1%F.S. 10mV/0.4mA LAN/RS232 2U
N6218-60-150 1 60V 150A 1,200W Voltage≤0.05%+0.05%F.S./Current≤0.1%+0.1%F.S. 1mV/2.5mA LAN/RS232 2U
N6218-150-150 1 150V 150A 1,800W Voltage≤0.05%+0.05%F.S./Current≤0.1%+0.1%F.S. 2.5mV/2.5mA LAN/RS232 2U
N6218-600-30 1 600V 30A 1,800W Voltage≤0.05%+0.05%F.S./Current≤0.1%+0.1%F.S. 10mV/0.5mA LAN/RS232 2U
Functions & Advantages
    • Adjustable CV loop feedback speed

Different voltage response speeds are required in different power applications. When the electronic load does not match with the power supply in response speed, it will cause parameter fluctuation, reduce the measuring accuracy, and even cause numerical oscillation and unsuccessful test.On both LCD and application software, N6200 provides three options for voltage response speed: high, medium and low, which can match various power supplies. It can not only improve the test efficiency but also reduce the cost of equipment, time and expenses.


Equivalent Series Resistance( ESR) test (Optional)

ESR is a principal parameter of battery or supercapacitor. N6200 series offers professional ESR measurement function,which can support multiple measurement standards, and possess the advantages of accurate results and stable repeated results.

The ESR measurement function absorbs current from the DUT under CC mode. When the current changes, the NGI internal resistance sensing circuit can accurately capture the voltage drop of DUT and calculate ESR value.

CR/CP function supported by hardware

NGI CP circuit has fast response and high accuracy. Compared with CP function by software, it works more stably and reliably without causing power peak or self-excitation due to voltage transient.

NGI CR circuit can improve the speed and stability of the control loop and prevent the loop from self-excitation, without participation of software for calculation.

Fuse melting time measurement
Fuse manufacturer is required to test the fuse melting time at different rates based on rated current. Take a rated 30A fuse for example. If the rate is 5 times, the Max. fuse melting current will be 150A. N6200 series can fully meet users' testing needs.

Detailed Photos


Product Parameters

Model N6206-60-50 N6206-150-50 N6206-600-10
Voltage 60V 150V 600V
Current 50A 50A 10A
Power 600W
Min. Operating Voltage 2V@50A 2V@50A 4.5V@10A
CC Mode
Range 0-5A 0-50A 0-5A 0-50A 0-1A 0-10A
Setting Resolution 0.1mA 1mA 0.1mA 1mA 0.1mA 1mA
Setting Accuracy (23±5ºC) Low range:0.1%+0.1%F.S., High range:0.1%+0.15%F.S.
CV Mode
Range 0-6V 0-60V 0-15V 0-150V 0-60V 0-600V
Setting Resolution 0.1mV 1mV 0.1mV 1mV 1mV 10mV
Setting Accuracy (23±5ºC) 0.05%+0.1%F.S.
CP Mode
Range 0-600W
Setting Resolution 10mW
Setting Accuracy (23±5ºC) 0.5%+1%F.S
CR Mode
Range 0.03~120Ω 0.5Ω~1200Ω 0.06Ω~300Ω 1.2Ω~3000Ω 1.12Ω~6000Ω 22.4Ω~60000Ω
Setting Resolution 16bits
Setting Accuracy (23±5ºC) 0.35%+26.04mS 0.35%+2.6mS 0.35%+10.41mS 0.35%+1.04mS 0.35%+0.52mS 0.35%+0.05mS
Slew Rate
Current 0.8-50A/ms 50-2500A/ms 0.8-50A/ms 50-2500A/ms 0.1-10A/ms 10-500A/ms
Voltage 0.5-25V/ms 25-250V/ms 10-60V/ms 60-600V/ms 5.0-250V/ms 250-2500V/ms
Power 0.8-50A/ms 50-2500A/ms 0.8-50A/ms 50-2500A/ms 0.1-10A/ms 10-500A/ms
Resistance 0.8-50A/ms 50-2500A/ms 0.8-50A/ms 50-2500A/ms 0.1-10A/ms 10-500A/ms
Accuracy (23±5ºC) (1+35%)*Setting value
Voltage Measurement
Range 0-6V 0-60V 0-15V 0-150V 0-60V 0-600V
Readback Accuracy (23±5ºC) 0.05%+0.1%F.S
Current Measurement
Range 0-5A 0-50A 0-5A 0-50A 0-1A 0-10A
Readback Accuracy (23±5ºC) 0.05%+0.1%F.S.
Power Measurement
Range 0-600W
Readback Accuracy (23±5ºC) 0.5%+1%F.S.
Dynamic Mode
T1&T2 0.025-60ms 1-60000ms 0.025-60ms 1-60000ms 0.025-60ms 1-60000ms
Resolution 1μs 1ms 1μs 1ms 1μs 1ms
Accuracy (23±5ºC) 1μs+100ppm 1ms+100ppm 1μs+100ppm 1ms+100ppm 1μs+100ppm 1ms+100ppm
Others
Interface LAN/RS232
AC Input Single phase, 220V AC±10%, frequency 47Hz~63Hz
Temperature Operating temperature: 0ºC~40ºC, storage temperature: -20ºC~60ºC
Operating Environment Altitude <2000m, relative humidity: 5%~90%RH(non-condensing), atmospheric pressure: 80~110kPa
Net Weight Approx. 13kg
Dimension 2U, 88.0(H)*482.0(W)*507.0(D)mm
Model N6212-60-100 N6212-150-100 N6212-600-20
Voltage 60V 150V 600V
Current 100A 100A 20A
Power 1200W
Min. Operating Voltage 2V@100A 2V@100A 4.5V@20A
CC Mode
Range 0-10A 0-100A 0-10A 0-100A 0-2A 0-20A
Setting Resolution 0.1mA 1mA 0.1mA 1mA 0.1mA 1mA
Setting Accuracy (23±5ºC) Low range:0.1%+0.1%F.S., High range:0.1%+0.15%F.S.
CV Mode
Range 0-6V 0-60V 0-15V 0-150V 0-60V 0-600V
Setting Resolution 0.1mV 1mV 0.1mV 1mV 1mV 10mV
Setting Accuracy (23±5ºC) 0.05%+0.1%F.S.
CP Mode
Range 0-1200W
Setting Resolution 10mW
Setting Accuracy (23±5ºC) 0.5%+1%F.S
CR Mode
Range 0.02~60Ω 0.3Ω~600Ω 0.03Ω~150Ω 0.6Ω~1500Ω 0.56Ω~3000Ω 11.2Ω~30000Ω
Setting Resolution 16bits
Setting Accuracy (23±5ºC) 0.35%+52mS 0.35%+5.2mS 0.35%+20.8mS 0.35%+2.08mS 0.35%+1mS 0.35%+0.1mS
Slew Rate
Current 1.6-100A/ms 100-5000A/ms 1.6-100A/ms 100-5000A/ms 0.3-20A/ms 20-1000A/ms
Voltage 0.5-25V/ms 25-250V/ms 10-60V/ms 60-600V/ms 5.0-250V/ms 250-2500V/ms
Power 1.6-100A/ms 100-5000A/ms 1.6-100A/ms 100-5000A/ms 0.3-20A/ms 20-1000A/ms
Resistance 1.6-100A/ms 100-5000A/ms 1.6-100A/ms 100-5000A/ms 0.3-20A/ms 20-1000A/ms
Accuracy (23±5ºC) (1+35%)*Setting value
Voltage Measurement
Range 0-6V 0-60V 0-15V 0-150V 0-60V 0-600V
Readback 0.05%+0.1%F.S
Accuracy (23±5ºC)
Current Measurement
Range 0-10A 0-100A 0-10A 0-100A 0-2A 0-20A
Readback Accuracy (23±5ºC) 0.05%+0.1%F.S.
Power Measurement
Range 0-1200W
Readback Accuracy (23±5ºC) 0.5%+1%F.S.
Dynamic Mode
T1&T2 0.025-60ms 1-60000ms 0.025-60ms 1-60000ms 0.025-60ms 1-60000ms
Resolution 1μs 1ms 1μs 1ms 1μs 1ms
Accuracy (23±5ºC) 1μs+100ppm 1ms+100ppm 1μs+100ppm 1ms+100ppm 1μs+100ppm 1ms+100ppm
Others
Interface LAN/RS232
AC Input Single phase, 220V AC±10%, frequency 47Hz~63Hz
Temperature Operating temperature: 0ºC~40ºC, storage temperature: -20ºC~60ºC
Operating Environment Altitude <2000m, relative humidity: 5%~90%RH(non-condensing), atmospheric pressure: 80~110kPa
Net Weight Approx. 14.5kg
Dimension 2U, 88.0(H)*482.0(W)*507.0(D)mm